Sign In | Join Free | My enlightcorp.com
China FLY AUTOMATION logo
FLY AUTOMATION
Automation Industry Expert . Focused on Pneumatic Components 15 years!
Verified Supplier

17 Years

Home > Diaphragm Repair Kit >

K7600 Nitrile K7601 fluororubber Diaphragm

FLY AUTOMATION
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

K7600 Nitrile K7601 fluororubber Diaphragm

Brand Name : FLY, AIRWOLF or others

Model Number : K7600 (Nitrile), K7601 (fluororubber)

Certification : CE

Place of Origin : China

MOQ : 1 piece

Price : price negotiable

Payment Terms : T/T in advance,Western Union,Paypal,Credit card

Supply Ability : 2000 pcs

Delivery Time : within 1-30 working days after payment

Packaging Details : Plastic bags,Boxes, Cartons, Pallets,or according to customer's requirement

Order code : K7600(Nitrile),K7601(fluororubber)

Material : NBR/fluororubber

Color : Black

Port size : G3INCH

Diameter : 200mm

Lifespan : 1 million cycles

Contact Now

K7600 Nitrile K7601 fluororubber Pulse Jet Valves Diaphragm Maintenance Package

Ordering Code: K7600 (Nitrile), K7601 (fluororubber)

Fit for: CA-76T,RCA-76T, CA-76MM, RCA-76MM

Description:

1. The diaphragm repair kits is for pulse jet valves CA-76T,RCA-76T, CA-76MM, RCA-76MM

2. Material: NBR/fluororubber

3. This repair kit has large air - outlet , so the air can get throgh very smoothly.

4. We use high quality material , the collection equipment efficiency can be improved , the energy loss also can be reduced.

5. FLY/AIRWOLF 7600(Nitrile),K7601(fluororubber) repair kit has unique geometric diaphragm design , high speed from multiple diaphragm to reach the highest peak in an instant.

6. We use high quality material , the collection equipment efficiency can be improved , the energy loss also can be reduced.

7. Its lifespan is about 1 million cycles.

Drawings size:

K7600 Nitrile K7601 fluororubber Diaphragm

1 . The design with integral compression fittings will facilitate installation because there is no need for threaded piping

2 . The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life, even under harsh conditions

3 . Integral pilot operated valves satisfy all relevant EC directives

4 . The pulse diaphragm valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation.

5 . The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust collector service applications

Competitive Advantage:

Our product features: Our Services Guarantee:
1) Competitive price 1) Prompt respond (Reply with 24 hours)
2) Good quality 2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging, 3) Registration support.
4) Produce according to Customers’ instruction 4) Photos/videos are available during production.
5) None delay shipment

5) Loading inspection, and send loading photos before shipment.

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.


Product Tags:

fluororubber FLY/AIRWOLF Diaphragm

      

K7600 FLY/AIRWOLF Diaphragm

      

K7601 FLY/AIRWOLF Diaphragm

      
Quality K7600 Nitrile K7601 fluororubber Diaphragm for sale

K7600 Nitrile K7601 fluororubber Diaphragm Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: FLY AUTOMATION
*Subject:
*Message:
Characters Remaining: (0/3000)